Framing & Drywall
What the work involves
Light-gauge steel stud framing for interior partitions, soffits, bulkheads and ceiling systems. We lay out from the architectural drawings and check it before anything gets covered, because a wall that is 3/4 of an inch off is a cabinet that does not fit two months later.
- Load-bearing and non-load-bearing partitions
- Soffits, bulkheads and drop ceilings
- Shaft walls and fire-rated assemblies
- Layout taken from the architectural drawings
- Blocking set for casework, fixtures and grab bars
Why steel, particularly here
Light-gauge steel does not feed termites, does not rot and does not warp with humidity — three things that matter more in South Florida than almost anywhere else in the country. It is dimensionally stable in a climate that is hard on wood, it is non-combustible, and it is what fire-rated and shaft-wall assemblies are tested and listed with.
It also arrives straight. A steel stud is the same width at the top as the bottom, every time, which is why the finished wall is flatter and why the trades after you have fewer surprises.
Layout is checked before anything gets covered
We lay out from the architectural drawings rather than from the existing walls, because the existing walls are frequently not where the drawings think they are. Openings get confirmed against the actual door and window schedule. Blocking goes in for casework, wall-hung fixtures, grab bars, televisions and anything else that will need something solid behind the board later.
Then it gets checked before it disappears. A partition that is three quarters of an inch out is invisible until it is a cabinet run that does not fit two months and several trades later, and at that point it is the most expensive kind of small mistake.
Assemblies that have to perform
Fire-rated partitions, shaft walls and sound assemblies are not framing with different stickers on it — they are tested systems, and they only perform as listed if they are built as listed. Stud gauge and spacing, track fastening, board layers and orientation, joint treatment and firestopping at penetrations are all part of the assembly, not details to be improvised on site.
Sound assemblies are the same story. Resilient channel installed hard against a stud is not resilient channel; it is an expensive way to build a normal wall.
Questions
Common questions
Do you do load-bearing steel framing?
We frame load-bearing and non-load-bearing partitions, but anything structural is built to an engineer's drawings and inspected. If your job needs that and does not have drawings yet, we will tell you at the walk-through rather than after the bid.
Can you frame to an existing out-of-square building?
Yes, and it is a normal part of renovation work in older South Florida buildings. The question is always whether to follow the building or hold the drawings, and it is a decision worth making deliberately — usually the finished rooms should be square even if the shell is not, and where the difference is absorbed needs to be agreed rather than discovered.
Do you supply the steel or do we?
Either. If you are supplying, send the spec with the drawings so we can confirm the gauge and profile match what the assemblies call for before anything is ordered.